What is the Surefuser+?

Surefuser+ is a single use elastomeric pump for continuous infusion therapy within the hospital or home environment. Simple, ergonomic design makes the Surefuser+ easy to fill, easy to connect, and even easier for you as a patient to manage.

Simply fill Surefuser+ with a standard 50ml Luer Lock syringe, attach the Surefuser+ to IV access and open the clamp. Surefuser+ is available empty, or pre-filled via our pharmacy compounding partners to suit your patient’s specific needs/prescription.

With abundant supporting data and clinical stability studies, a clinician and patient can use Surefuser+ with confidence.

Surefuser+ Instruction

PCA Instructions

Troubleshooting Guide

Make sure that the Clamp is open and that the Infusion Line or the connected catheter don’t have any bends and twists as these can cause fluctuations in the infusion rate. Also check the Filter for bubbles which you can remove by simply tapping it gently. If you cannot identify any obvious issues then please contact your nurse or Consultant at the Hospital as soon as possible.

Although scheduled end time has past, there is considerable residual drug left in Surefuser +

Call your hospital to determine if treatment can be continued or if it should be stopped. In the event treatment should be stopped, close the clamp on the infusion line and follow the guidelines provided to you by the hospital. In case of severe complications, call emergency services.

Drug solution has disappeared before scheduled time.

Call your hospital to determine if treatment can be continued or if it should be stopped. In the event treatment should be stopped, close the clamp on the infusion line and follow the guidelines provided to you by the hospital. In case of severe complications, call emergency services.

Close the clamp immediately. If leaking from the infusion line, close the clamp above the point where the leakage occurs. If leaking from one of the connections, check if they are closed tight. Remember to wear protective gloves while doing so. If leaking from the pump housing, place it in a plastic bag. Report all leakages to your hospital and follow their advice. If the medication came into contact with your skin, follow the guidelines provided by your hospital. In case of severe complications, call emergency services.

If none of the above resolved the issue, kindly contact to the supplier.
Please keep the actual sample for investigation. 

Infusion progression

The family or carers should note the movement of the blue infusion line as advised by the nurse (during the day) on the monitoring label.

• For volumes of 50 ml and 100 ml, each interval of 1 corresponds approximately to 10 ml.
• For volumes of 150 ml and 250 ml, each interval of 1 corresponds approximately to 50 ml.
• For the largest pump of 300 ml, each interval of 1 corresponds approximately to 100 ml.

Caution

Surefuser+ FAQ

Make sure that the Clamp is open and that the Infusion Line or the connected catheter don’t have any bends and twists as these can cause fluctuations in the infusion rate. Also check the Filter for bubbles which you can remove by simply tapping it gently. If you cannot identify any obvious issues then please contact your nurse or Consultant at the Hospital as soon as possible.

Your Clinic will advise you how to keep your Surefuser+ clean. For further advice on cleaning please contact your nurse. WARNING: You should avoid using any substances to clean your Surefuser+ which may contain chemicals/alcohol that could damage the Casing or Infusion Line.

Yes, however, please remember that Surefuser+ must stay out of direct sunlight and should not be exposed to high temperatures. Please ensure the flow regulator is securely attached to your skin. The pump should be kept in its carrying bag, as the device must remain at room temperature.

Surefuser+ does not contain any metal parts and may therefore be worn safely while undergoing an MRI. Consult your HCP to ensure that your infusion port and/or catheter is suitable for an MRI.

Your Surefuser+ can be worn anywhere on your body, for example a pocket or in a handbag or Surefuser+ carrying case. The main thing in selecting a place is that it is comfortable and protects the device from damage, sunlight, water or extreme temperatures. The Flow Controller needs to be taped to your body at all times as it uses the temperature of your skin (32°C) in order to function properly.

It is essential that you keep the Flow Controller and Filter dry at all times. You can bathe but you MUST keep your Surefuser+ and Infusion Line away from any contact with the water. Your nurse will advise you on the best protection for your Surefuser+. Should you use tape to cover the device whilst bathing, make sure that it does not restrict the Flow Controller or the Filter from functioning effectively.

Please check with your healthcare provider if it is ok for you to shower or take a bath. Please make sure that the pump housing and the infusion line are not submerged or exposed to a direct stream of water. Surefuser+ is water resistant, but not waterproof. The filter on the bottom of the pump and in the infusion line should not come into contact with water or soap.

Your Surefuser+ has been designed to operate without you having to do anything. Please simply check it periodically to make sure your medication is infusing and for any noticeable leaks or damage. If you identify an issue please contact your nurse or Consultant at the Hospital.

Your Surefuser+ needs to be kept at room temperature at all times and so please avoid exposure to sunlight and extreme cold.

No – it should only ever be used once and then be disposed of.

Yes. We recommend that you keep Surefuser+ in a secured place on or near your bed and at the same head height as your sleeping position. Do not keep it under your bed covers, as the Surefuser+ needs to stay at room temperature.

Yes – this small bag provided is a reusable accessory and can be hand washed in a light soapy solution. Please ensure it is dry before re-use

This FAQ is a guide and should not replace or take precedence over the instructions provided by your health care professional. If you have any concerns please contact your health care professional.

Troubleshooting Guide

Surefuser+ Features

Temperature

The flow regulator, which regulates how fast the medication flows, is calibrated at skin temperature. Therefore, it is important to keep the flow regulator attached to your skin at all times.

Balloon Pump Position

The flow regulator, which regulates how fast the medication flows, is calibrated at skin temperature. Therefore, it is important to keep the flow regulator attached to your skin at all times. The device itself is best kept at room temperature.

Dual filter

Do not clean or disinfect the filter with soap, detergent, or alcohol. Note that perfume contains alcohol, so avoid spraying perfume near the filter.